  • Introduction of liquid thermal shock chamber

    Introduction of liquid thermal shock chamber

    Liquid thermal shock chamber (also known as a liquid-bath thermal shock chamber) is a type of equipment used for accelerated reliability stress testing. It features two separate temperature-controlled liquid bathsone for high temperatures and one for low temperatures. A basket mechanism rapidly and alternately immerses the test specimen into these high- and low-temperature heat-transfer liquid media. Leveraging the superior heat-transfer capacity of liquids compared to air, the system achieves e...

    Find out More Oct 26, 2026
  • Test standard and application of ozone test chamber

    Test standard and application of ozone test chamber

    Fundamental general methods: GB/T 7762-2014 (static), GB/T 13642-2015 (dynamic), ISO 1431-1:2024, and ASTM D1149, GB/T 35804 is the method for calibrating ozone concentration within the test chamber. 1. Automotive Industry (Largest Volume of Usage) Specimens: Door weatherstripping, sunroof seals, wiper blades, engine hoses, brake hoses, dust boots, vibration-damping bushings, tire sidewalls, water hoses, fuel hoses. Standards: - GB/T 7762-2014: Static testing (seals, tire sidewalls) - GB/T 13642...

    Find out More Oct 13, 2026
  • What are the common consumables for climate chambers?

    What are the common consumables for climate chambers?

    1.Waterway / Humidification system consumables (Highest wear, most frequent replacement) Humidification tube / Stainless steel heating water jacket ​Function: Heats purified water to generate steam for humidification; prone to perforation and leakage caused by long-term scale corrosion.Replacement cycle: 612 months (3 months if water quality is poor). Humidification tank / Water tank seal Prevents leakage from the water reservoir, rubber hardens and ages due to prolonged high-temperature expos...

    Find out More Sep 17, 2026
  • Introduction of the Sulfur dioxide (SO₂) corrosion test chamber

    Introduction of the Sulfur dioxide (SO₂) corrosion test chamber

    Equipment definition and corrosion principle: The sulfur dioxide test chamber (also known as a gas corrosion test chamber) is designed to simulate acidic, sulfur dioxide-laden atmospheressuch as those found in industrial zones, areas affected by acid rain, or chemical plant vicinities. It accelerates the assessment of the resistance of metal platings, coatings, electronic contacts, and hardware components to sulfur-induced corrosion. Corrosion mechanism: Within the sealed chamber, a high-tempera...

    Find out More Sep 17, 2026
  • Differences between UVA-340 and UVB-313 light tubes

    Differences between UVA-340 and UVB-313 light tubes

    1. Wavelength and spectrum (Key difference) UVA-340: 295365 nm Perfectly matches the UV spectrum of sunlight at the Earths surface, contains virtually no short-wave UV that does not exist in the natural environment, resulting in aging effects that closely mirror real-world outdoor exposure. UVB-313: 280315 nm Contains significant amounts of short-wave UV rarely found in nature; possesses extremely high photon energy. It accelerates aging 23 times faster than UVA-340 and is prone to producing art...

    Find out More Sep 14, 2026
  • How often should the UVA or UVB lamps in a UV aging chamber be replaced?

    How often should the UVA or UVB lamps in a UV aging chamber be replaced?

    Under what circumstances do the UV lamps (UVA/UVB) in a UV aging chamber need to be replaced? 1. Rated service life (Industry standard) 1) UVA-340 light tube Rated effective life: 1500 hours Slow filament degradation, stable spectrum, and more gradual decay under high-humidity conditions (60~90% RH). 2) UVB-313 light tube Higher short-wave energy and significant filament heat generation result in a shorter lifespan: 1,0001,500 hours. Long-term operation in 90% RH condensation mode can further re...

    Find out More Sep 14, 2026
  • Complete Selection Considerations for Low-Pressure Test Ports

    Complete Selection Considerations for Low-Pressure Test Ports

    This section covers 9 core dimensions: vacuum pressure rating, operating temperature, wiring medium, sealing structure, electrical performance, material, usage frequency, standard compliance, and quantity allowance. It encompasses two types of structures: rubber-pressurized sealing ports and KF vacuum feedthrough ports. I. Vacuum/Minimum Pressure Rating (First Priority, Determines Port Type) The higher the negative pressure and altitude, the more stringent the sealing requirements. This directly...

    Find out More Aug 22, 2026
  • Similarities and differences between altitude chamber and vacuum oven

    Similarities and differences between altitude chamber and vacuum oven

    I. Similarities for altitude chamber and vacuum oven 1. Same Basic Structure Both utilize a sealed, pressure-resistant stainless steel chamber, vacuum unit (rotary vane vacuum pump), vacuum gauge, sealed door, PID temperature control, and programmable controller. They all rely on evacuation to create a negative pressure environment, and the chambers are reinforced to prevent deformation during vacuuming. 2. Overlapping Physical Principles Both achieve low-temperature dehydration, solvent removal...

    Find out More Aug 22, 2026
  • Two spray nozzle features and selection of salt spray test chamber

    Two spray nozzle features and selection of salt spray test chamber

    We commonly use two types of salt spray nozzles in salt spray test chambers: quartz glass nozzles and titanium alloy nozzles. Below are the characteristics of these two nozzles; customers can choose the appropriate nozzle based on their demand. 1. Glass Nozzle (Borosilicate/Quartz) ✅ Advantages - High atomization precision: smooth inner wall, uniform pore size, droplets 1-5m, uniform settling, conforming to GB/T 10125 and ISO 9227. - Strong chemical inertness: Resistant to NSS/AASS/CASS salt s...

    Find out More May 06, 2026
  • Precautions for Using Industrial Tunnel Furnaces

    Precautions for Using Industrial Tunnel Furnaces

    I. Precautions Before Start-up 1. Check that the power supply, wiring, and grounding wire are secure, free from aging, damage, or loose connections. Operation with a single phase is strictly prohibited. 2. Check that the heating elements, temperature control probes, and thermocouples are intact, and that the probes are not misaligned or have accumulated ash or coke. 3. Clean the furnace thoroughly, removing any debris, oil, or flammable materials. Ensure the ventilation and dehumidification syst...

    Find out More Apr 20, 2026
  • Comparison of the Advantages and Disadvantages of Chillers, Cooling Towers, and Air Conditioning Cond

    Comparison of the Advantages and Disadvantages of Chillers, Cooling Towers, and Air Conditioning Cond

    Thermal shock chambers, rapid temperature change chambers, and walk-in constant temperature and humidity chambers, if using water cooling way for heat dissipation , they require use chillers, cooling towers, or air conditioning condensate. Below is a comparison of the advantages and disadvantages of these three methods for equipment cooling/circulating water. First, clarify the application: Generally used for testing machines, cold shock chambers, injection molding, equipment heat dissipation, a...

    Find out More Apr 08, 2026
  • UV Aging Chamber vs. Xenon Lamp Aging Chamber

    UV Aging Chamber vs. Xenon Lamp Aging Chamber

    I. Similarities for UV aging chamber and xenon lamp aging chamber: - Both are used for weathering and light aging tests, simulating fading, cracking, powdering, and embrittlement caused by sunlight exposure. - Both are artificially accelerated aging processes, faster and more repeatable than outdoor exposure. - Both can be equipped with spray, condensation, and temperature and humidity control to simulate rain and dew environments. - Test results are used for material selection, quality inspecti...

    Find out More Mar 23, 2026
  • One day of salt spray testing is equivalent to simulating how many days of natural salt spray corrosi

    One day of salt spray testing is equivalent to simulating how many days of natural salt spray corrosi

    In industrial production and product design, the corrosion resistance of materials is a crucial consideration. Especially in marine, coastal, or high-humidity environments, the corrosion rate of materials accelerates significantly, affecting not only the aesthetics of products but, more importantly, their functionality and safety. To quickly assess the corrosion resistance of materials in these environments, salt spray testing has emerged. This article will delve into salt spray testing, particu...

    Find out More Feb 28, 2026
  • Water selection for salt spray test chamber

    Water selection for salt spray test chamber

    Salt spray test chamber must use deionized or distilled water. Tap water and mineral water are strictly prohibited. Core Water Quality Requirements (National Standard/International Standard): Conductivity: 20 S/cm (25℃) Purity: Free of impurities, heavy metals, minerals, and organic matter. Applications: This type of water is used for preparing salt solutions, sealing tanks, saturators, and water replenishment. Why cant tap water/mineral water be used for testing? Containing calcium, magnesium...

    Find out More Feb 28, 2026
  • Can constant temperature and humidity chamber gauze be used for humidity testing in composite salt sp

    Can constant temperature and humidity chamber gauze be used for humidity testing in composite salt sp

    The answer is no. Please read below mentioned three reasons. Material and Manufacturing Mismatch: Constant temperature and humidity chamber wet-bulb gauze is mostly made of ordinary degreased cotton/blended fabrics, with short fibers and low density. Composite salt spray (salt spray + humidity + drying cycle) will cause the gauze to harden rapidly, form salt deposits, and shed fibers, clogging the nozzle and contaminating the sample. 2. Poor Corrosion Resistance: Salt spray contains high concent...

    Find out More Feb 28, 2026
  • Can a salt spray test chamber be placed in the same room as other equipment?

    Can a salt spray test chamber be placed in the same room as other equipment?

    It depends on the types of equipment in the same room. Some can, some cannot. 1. Equipment that can be placed together: - Ordinary non-metallic equipment (plastic, cement, rust-free) - Industrial equipment that has been properly protected against corrosion and sealed. 2. Equipment that absolutely cannot be placed in the same room: - Precision instruments, multimeters, oscilloscopes, power supplies - Computers, servers, monitoring equipment - Electroplated/painted/hardware finished products, prod...

    Find out More Feb 28, 2026
  • What kind of water or salt water is needed for salt spray testing?

    What kind of water or salt water is needed for salt spray testing?

    Salt spray test chambers have strict standards for water and salt water, which directly determine the reliability of the results and the lifespan of the equipment. I. Test Water (Required) ✅ Qualified Water (Choose one) - Deionized water/Distilled water (Preferred) - Conductivity: 20S/cm (Grade I water 5S/cm is more stable) - Total dissolved solids (TDS): 200ppm - Free of calcium, magnesium, iron, chloride, carbonate, and other impurities - Grade II deionized water (when conditions are limited...

    Find out More Feb 24, 2026
  • How long for a one climate chamber use?

    How long for a one climate chamber use?

    The lifespan of a constant temperature and humidity chamber/climate chamber is affected by a variety of factors. Generally speaking, qualified equipment, with normal use and maintenance, typically has a service life of around 8-15 years. What should we do to extend the climate chamber service time, below are the influence factors for the service time. Specific lifespan variations are primarily determined by the following factors: - Equipment quality: Equipment from reputable brands and using hig...

    Find out More Jul 30, 2025
  • How to choose air-cooled/water cooled xenon lamp weathering chcamber?

    How to choose air-cooled/water cooled xenon lamp weathering chcamber?

    How to choose air-cooled/water cooled xenon lamp weathering chcamberis primarily based on the test standard, power requirements, sample characteristics, and application scenario. The key difference lies in the xenon lamp heat dissipation method and applicable scope: I. Applications of Air-Cooled Xenon Lamps - Low- and medium-power testing: Xenon lamps have low power (typically below 3.5kW) and generate relatively little heat. Air cooling (using fans to force air circulation to dissipate heat) ca...

    Find out More Jul 30, 2025
  • Application of lineanr and nonlinear temp. ramp test chambers

    Application of lineanr and nonlinear temp. ramp test chambers

    The application areas of linear and nonlinear temperature ramp test chambers are primarily determined by the degree to which their temperature characteristics match the test requirements, as follows: 1. Main Application Areas of Linear Temperature Ramp Test Chambers Because they achieve uniform and stable temperature changes, linear temperature ramp test chambers are suitable for testing scenarios requiring standardization and high repeatability. Typical applications include: - Electronics and S...

    Find out More Jul 30, 2025