In industrial production and product design, the corrosion resistance of materials is a crucial consideration. Especially in marine, coastal, or high-humidity environments, the corrosion rate of materials accelerates significantly, affecting not only the aesthetics of products but, more importantly, their functionality and safety. To quickly assess the corrosion resistance of materials in these environments, salt spray testing has emerged. This article will delve into salt spray testing, particu...
Find out More Feb 28, 2026Salt spray test chamber must use deionized or distilled water. Tap water and mineral water are strictly prohibited. Core Water Quality Requirements (National Standard/International Standard): Conductivity: 20 S/cm (25℃) Purity: Free of impurities, heavy metals, minerals, and organic matter. Applications: This type of water is used for preparing salt solutions, sealing tanks, saturators, and water replenishment. Why cant tap water/mineral water be used for testing? Containing calcium, magnesium...
Find out More Feb 28, 2026The answer is no. Please read below mentioned three reasons. Material and Manufacturing Mismatch: Constant temperature and humidity chamber wet-bulb gauze is mostly made of ordinary degreased cotton/blended fabrics, with short fibers and low density. Composite salt spray (salt spray + humidity + drying cycle) will cause the gauze to harden rapidly, form salt deposits, and shed fibers, clogging the nozzle and contaminating the sample. 2. Poor Corrosion Resistance: Salt spray contains high concent...
Find out More Feb 28, 2026It depends on the types of equipment in the same room. Some can, some cannot. 1. Equipment that can be placed together: - Ordinary non-metallic equipment (plastic, cement, rust-free) - Industrial equipment that has been properly protected against corrosion and sealed. 2. Equipment that absolutely cannot be placed in the same room: - Precision instruments, multimeters, oscilloscopes, power supplies - Computers, servers, monitoring equipment - Electroplated/painted/hardware finished products, prod...
Find out More Feb 28, 2026Salt spray test chambers have strict standards for water and salt water, which directly determine the reliability of the results and the lifespan of the equipment. I. Test Water (Required) ✅ Qualified Water (Choose one) - Deionized water/Distilled water (Preferred) - Conductivity: 20S/cm (Grade I water 5S/cm is more stable) - Total dissolved solids (TDS): 200ppm - Free of calcium, magnesium, iron, chloride, carbonate, and other impurities - Grade II deionized water (when conditions are limited...
Find out More Feb 24, 2026The lifespan of a constant temperature and humidity chamber/climate chamber is affected by a variety of factors. Generally speaking, qualified equipment, with normal use and maintenance, typically has a service life of around 8-15 years. What should we do to extend the climate chamber service time, below are the influence factors for the service time. Specific lifespan variations are primarily determined by the following factors: - Equipment quality: Equipment from reputable brands and using hig...
Find out More Jul 30, 2025How to choose air-cooled/water cooled xenon lamp weathering chcamberis primarily based on the test standard, power requirements, sample characteristics, and application scenario. The key difference lies in the xenon lamp heat dissipation method and applicable scope: I. Applications of Air-Cooled Xenon Lamps - Low- and medium-power testing: Xenon lamps have low power (typically below 3.5kW) and generate relatively little heat. Air cooling (using fans to force air circulation to dissipate heat) ca...
Find out More Jul 30, 2025The application areas of linear and nonlinear temperature ramp test chambers are primarily determined by the degree to which their temperature characteristics match the test requirements, as follows: 1. Main Application Areas of Linear Temperature Ramp Test Chambers Because they achieve uniform and stable temperature changes, linear temperature ramp test chambers are suitable for testing scenarios requiring standardization and high repeatability. Typical applications include: - Electronics and S...
Find out More Jul 30, 2025The key difference between a cyclic salt spray test chamber and a standard salt spray test chamber lies in the complexity of the simulated environment and the diversity of test conditions. The specific differences are as follows: 1. Differences in Simulated Environments - Standard salt spray test chambers can only simulate a single salt spray corrosion environment. They primarily evaluate the corrosion resistance of products in a constant salt spray environment by continuously or intermittently...
Find out More Jul 30, 2025Selecting dust suitable for a dust test chamber requires considering the test standard, dust characteristics, and test objectives to ensure accurate and comparable test results. The key steps and key points are as follows: 1. Prioritize compliance with test standard requirements - Identify the specified dust type based on the products corresponding international/industry standards (such as IEC 60529, ISO 12103, GB/T 4208, etc.). - Most Common Standards: Almost all common standards require the us...
Find out More Jul 08, 2025To choose a suitable salt spray test chamber sample rack, you need to consider the material, structure, function and test requirements from multiple dimensions. The core points are as follows: 1. Select materials according to sample materials and test purposes - Conventional metal/coated samples: Choose PVC or PP materials, which are resistant to salt spray corrosion and low cost (such as automotive accessories, hardware). - High-end or special environment materials (such as aerospace, semicondu...
Find out More Jun 27, 2025When we communicate with customers about thermal shock chamber, we will mention the cooling methods, air cooling and water cooling. At this time, customers will ask us about the difference between the two cooling methods. The following is a comparison of the advantages and disadvantages of the two cooling methods in terms of temperature control efficiency, energy consumption, maintenance, etc. A. Water cooling thermal shock chamber Advantages: 1. High temperature control accuracy: - The water ci...
Find out More Jun 09, 2025Thetemperatureuniformityofthenitrogenovenisaffectedbymanyfactors,thecoreofwhichliesintheequipmentdesign,operatingparametersandmaintenance,asfollows: 1.Equipmentdesignandstructure -Airductandfanlayout: -Insufficientfanairvolume(suchas20times/hourventilation)orunevenairpressure,resultinginpoornitrogencirculationand largetemperaturedeviationinlocalareas; -Unreasonableairductdesign(suchaspoorsymmetrybetweentheairoutletand thereturnairoutlet),whicheasilyforms airflowdeadcorners(suchasthecornersofthec...
Find out More Jun 11, 2025Electronics Industry( Semiconductor and Chip Manufacturing) In the manufacturing process of semiconductors and chips, the requirements for the production environment are extremely strict. The high temperature of 400℃ can meet the needs of some special processes, such as heat treatment and reflow soldering of chips. The inert atmosphere formed by filling with nitrogen can effectively prevent electronic components from oxidation, corrosion or moisture at high temperatures, and avoid the impact o...
Find out More Jun 27, 2025Drying of APIs: Many APIs contain a large amount of water or other volatile solvents after synthesis or extraction, which need to be removed by drying. The drying oven can quickly remove these water and solvents at a lower temperature, avoiding degradation or inactivation of the drug due to high temperature, and ensuring the quality and stability of the API. Drying and purification of intermediates: In the process of drug synthesis, some intermediates are often produced, which may need to be dri...
Find out More Jun 27, 2025The nitrogen used in nitrogen ovens must meet the following key requirements to ensure the safety and reliability of equipment performance and application scenarios: 1. Purity requirements - Core indicators: Nitrogen purity usually needs to be 99.9% (i.e. three nines), and some high-precision scenarios (such as medicine and semiconductors) may require 99.99% (four nines) or higher. - Reasons: - The oxygen, moisture, impurities, etc. contained in low-purity nitrogen may cause oxidation, moisture...
Find out More May 30, 2025The working principle of the double layer nitrogen oven is to create an oxygen-free environment by filling it with nitrogen, thereby ensuring that the baked items will not undergo oxidation reactions at high temperatures. The double layer nitrogen oven is mainly composed of a chamber, a heating system, a nitrogen control system, a ventilation system, etc. Before use, the samples need to be placed on a baking tray or grill, and then placed in the oven. The heating system will heat the nitrogen to...
Find out More May 30, 2025Importance of changing gauze: The gauze in the constant climate chamber is mainly used to maintain the measurement of wet-bulb humidity, which is calculated by the wet-dry-bulb method. The state of the gauze directly affects the accuracy of humidity measurement. When the gauze turns yellow, hardens, or the water absorption becomes poor, it needs to be replaced, because this will affect the humidity reading, which may cause the humidity to fail to decrease and the displayed value to continue to b...
Find out More May 29, 2025When the IEC60529 dust test chamber is conducting dust tests, the type of dust used needs to meet certain standards and requirements. According to relevant information, the following is the relevant content about the use of dust in the IEC60529 dust test chamber: Dust type: The dust used in the dust test chamber mainly includes inorganic dust, organic dust and mixed dust. Inorganic dust includes mineral dust, metallic dust and artificial inorganic dust; organic dust includes animal dust, plant d...
Find out More Feb 28, 2025-86℃ vertical ultra-low temperature chamber is our new designed chamber, it is a refrigeration equipment that can reach -86℃ low temperature, its temp. range is -40℃~-86℃. It is mainly used for storing viruses, germs, red blood cells, white blood cells, skin, bones, bacteria, semen, biological products, ocean products, electronic devices, low temperature testing of special materials, etc....
Find out More Feb 28, 2025